Access Hub
184,00 €
Enterprise Access Hub
EAH-8
924,00 €
Enterprise-grade access hub with entry and exit control up to eight doors and battery backup support.

(8) Lock terminals (12V or Dry)

(8+8) Inputs for request-to-exit devices and door position sensors

(8) PoE ports for Access Readers

(4) AUX terminals for chimes, sirens, or door openers

(1) Battery backup input (32–48V)

Installation Guide
Technical Specifications
Mechanical
Dimensions 379 x 355 x 105 mm (15 x 14 x 4.1")
WeightDevice: 9.1 kg (20 lb)
Mount: 624 g (1.4 lb)
Enclosure material SGCC housing with PC cover
Mounting material SGCC wall mount plate
Hardware
Networking interface (10) 10/100/1000 Base-T
Power methodUniversal input, 100–240V AC, Max. 4.4A, 50/60Hz
32–48V DC Lead Acid Battery, Max. 7.5A @32V
Power supplyAC/DC, internal
Max. power consumption 240W
PoE interface(8) PoE (Pins 1, 2+; 3, 6-)
Voltage range PoE mode44–57V DC
Total available PoE60W
Max. PoE wattage per port15.4W
LEDsSystem: white/blue
Output relays: steady white
Ethernet: flashing white
Button(1) Factory-reset
Digital input(8) Inputs for request-to-exit devices
(8) Inputs for door position sensors
(1) Emergency
Dry output relay(8) Lock terminals (12V or Dry)
(4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered output relayLock: 12V DC, 1A/ Dry
Aux: Dry only
Recommend max. cable length
18 AWG
UACC-Cable-DoorLockRelay length
20
AWG length

22
AWG length

24
AWG length

UA-Lock-Electric
(400mA)
100 m
(328
ft)
66 m
(217
ft)
42 m
(138
ft)
25 m
(82
ft)
UA-Lock-Magnetic-270kg
(800mA)
46 m
(151
ft)
30 m
(98
ft)
20 m
(66
ft)
12 m
(29
ft)
UA-Lock-Magnetic-540kg
(500mA)
80 m
(262
ft)
51 m
(167
ft)
32 m
(105
ft)
20 m
(66
ft)
Other locks
(1A)
36 m
(118
ft)
24 m
(79
ft)
15 m
(49
ft)
9 m
(30
ft)
Operating environmentIndoor use only
Ambient operating temperature 0 to 40° C (32 to 104° F) 
Ambient operating humidity5 to 95% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelEAH-8, Ver 01
LED
SystemSteady blue: adopted, device is ready
Steady white: pending adoption
Blinking white/blue: upgrading firmware
Breathing white: system initiating
Software
Management application UniFi Access: Version 1.22.17 and later